Skip to Content

Molded Case Circuit Breakers

Select Sub Categories Below

WEG Breaker 400 Amp Frame 300 Amp Trip 3 pole 100 K MCCB
Frame Size: 400 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 300
Trip Unit Type: Thermal and magnetic adjust
1,504.00 4,700.00 1504.0 USD
WEG Breaker 400 Amp Frame 400 Amp Trip 3 pole 65 K MCCB
Frame Size: 400 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 400
Trip Unit Type: Thermal and magnetic adjust
1,184.00 3,700.00 1184.0 USD
WEG Breaker 400 Amp Frame 300 Amp Trip 3 pole 65 K MCCB
Frame Size: 400 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 300
Trip Unit Type: Thermal and magnetic adjust
1,184.00 3,700.00 1184.0 USD
WEG Breaker 250 Amp Frame 250 Amp Trip 3 pole 35 K MCCB
Frame Size: 250 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 250
Trip Unit Type: Fixed Thermal and Adjustable Magnetic
496.00 1,550.00 496.0 USD
WEG Breaker 250 Amp Frame 250 Amp Trip 3 pole 100 K MCCB
Frame Size: 250 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 250
Trip Unit Type: Fixed Thermal and Adjustable Magnetic
768.00 2,400.00 768.0 USD
WEG Breaker 250 Amp Frame 250 Amp Trip 3 pole 65 K MCCB
Frame Size: 250 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 250
Trip Unit Type: Fixed Thermal and magnetic adjust
656.00 2,050.00 656.0 USD
WEG Breaker 2500 Amp Frame 2500 Amp Trip 3 pole 100 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 2500 A
Trip Unit Type: Electronic Trip With Maintenance
12,128.00 37,900.00 12128.0 USD
WEG Breaker 2500 Amp Frame 2000 Amp Trip 3 pole 100 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 2000 A
Trip Unit Type: Electronic Trip With Maintenance
11,520.00 36,000.00 11520.0 USD
WEG Breaker 2500 Amp Frame 1600 Amp Trip 3 pole 100 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 1600 A
Trip Unit Type: Electronic Trip With Maintenance
11,168.00 34,900.00 11168.0 USD
WEG Breaker 2500 Amp Frame 2500 Amp Trip 3 pole 100 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 2500
Trip Unit Type: Electronic Trip
11,264.00 35,200.00 11264.0 USD
WEG Breaker 2500 Amp Frame 2000 Amp Trip 3 pole 100 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 100 Kaic 100%
Current Rating: 2000
Trip Unit Type: Electronic Trip
10,656.00 33,300.00 10656.0 USD
WEG Breaker 2500 Amp Frame 2500 Amp Trip 3 pole 65 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 2500 A
Trip Unit Type: Electronic Trip With Maintenance
11,200.00 35,000.00 11200.0 USD
WEG Breaker 2500 Amp Frame 2000 Amp Trip 3 pole 65 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 2000 A
Trip Unit Type: Electronic Trip With Maintenance
10,656.00 33,300.00 10656.0 USD
WEG Breaker 2500 Amp Frame 1600 Amp Trip 3 pole 65 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 1600 A
Trip Unit Type: Electronic Trip With Maintenance
10,336.00 32,300.00 10336.0 USD
WEG Breaker 2500 Amp Frame 2500 Amp Trip 3 pole 65 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 2500
Trip Unit Type: Electronic Trip
10,368.00 32,400.00 10368.0 USD
WEG Breaker 2500 Amp Frame 2000 Amp Trip 3 pole 65 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 2000
Trip Unit Type: Electronic Trip
9,824.00 30,700.00 9824.0 USD
WEG Breaker 2500 Amp Frame 1600 Amp Trip 3 pole 65 K MCCB
Frame Size: 2500 Amps
Interrupt Current: 65 Kaic 100%
Current Rating: 1600
Trip Unit Type: Electronic Trip
9,472.00 29,600.00 9472.0 USD
WEG Breaker 225 Amp Frame 80 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 80
Trip Unit Type: Thermal adjust magnetic fixed
232.96 728.00 232.96 USD
WEG Breaker 225 Amp Frame 70 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 70
Trip Unit Type: Thermal and magnetic fixed
212.80 665.00 212.8 USD
WEG Breaker 225 Amp Frame 60 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 60
Trip Unit Type: Thermal adjust magnetic fixed
212.80 665.00 212.8 USD
WEG Breaker 225 Amp Frame 50 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 50
Trip Unit Type: Thermal adjust magnetic fixed
212.80 665.00 212.8 USD
WEG Breaker 225 Amp Frame 40 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 40
Trip Unit Type: Thermal adjust magnetic fixed
212.80 665.00 212.8 USD
WEG Breaker 225 Amp Frame 30 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 30
Trip Unit Type: Thermal and magnetic fixed
212.80 665.00 212.8 USD
WEG Breaker 225 Amp Frame 225 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 225
Trip Unit Type: Thermal and magnetic fixed
496.00 1,550.00 496.0 USD
WEG Breaker 225 Amp Frame 200 Amp Trip 3 pole 35 K MCCB
Frame Size: 225 Amps
Interrupt Current: 35 Kaic 80%
Current Rating: 200
Trip Unit Type: Thermal and magnetic fixed
496.00 1,550.00 496.0 USD